Watershed Runoff Calculator: SCS Curve Number & Peak Flow
Get runoff depth, volume, time of concentration and peak discharge for any farm catchment, then size the culvert and farm pond and see the cost. Free, worldwide, any currency.
1. Catchment & Storm
2. Pond & Culvert Costs
Storm Comparison (same catchment)
| Scenario | Rainfall | Runoff depth | Volume | Peak flow |
|---|
Runoff & Peak Flow Design Guide
The SCS Curve Number method estimates how much rainfall becomes runoff from land cover, soil group and wetness. Runoff volume sizes ponds and storage; peak discharge sizes culverts, channels and spillways.
Formulas Used
S (mm) = 25400 / CN − 254
Ia = λ × S
Q (mm) = (P − Ia)² / (P − Ia + S), for P > Ia
AMC-I: CN = 4.2·CN / (10 − 0.058·CN)
AMC-III: CN = 23·CN / (10 + 0.13·CN)
Tc (min) = 0.0195 · L0.77 · S−0.385 (L in m, S in m/m)
Peak qp = qu × A × Q (TR-55 Type II graphical method)
Culvert (full flow) Q = (0.3117/n) · D8/3 · S1/2, n = 0.013
Peak flow uses the US TR-55 Type II rainfall distribution. If your region has a different storm pattern, treat the peak as a first estimate and check it against local design data. Tc is clamped to 0.1-10 hours and Ia/P to 0.1-0.5, the valid range of the method. Culvert sizing ignores headwater and inlet control.
FAQ
Which design storm should I use? Use the 24-hour rainfall for your chosen return period (for example 10 or 25 years) from local rainfall data.
What does AMC mean? Antecedent moisture: dry (I), average (II) or wet (III) soil before the storm. Wet soil gives more runoff.
Is this valid for large watersheds? No. The method suits small catchments, roughly under 800 ha. Use dedicated hydrologic modelling for larger basins.
© AgroEngineeringZone.com — Results are planning estimates only, based on general assumptions. They are not a substitute for professional engineering design or local advice. AgroEngineeringZone.com is not liable for decisions made using this tool.